Step By Step Guide to Luminex Bioplex studies in Drug Development

Luminex multiplex bioassay makes it possible to analyze multiple analytes in a single reaction. This makes it possible to get more data from a small sample volume. Luminex assay also need a shorter timeframe than conventional immunoassay methods.

Much of this is made possible by the use of microspheres or the color-coded beads used with this system. The underlying xMap technology forms a key element that allows these beads to quantitate and run multiple analytes. This underlying technology is used in several systems, including Bio-Rad's Bio-Plex multiplex system. Therefore, you can as easily use a bioplex assay to handle your immunoassay requirements.

There are some considerations to be made and steps to be followed. Here are the key steps that aid Luminex Bioplex studies in drug development.

Proper Sample Preparation Defines Luminex Bioplex Studies

Sample preparation with attention to detail will define the results of any study. An error in sample preparation can be magnified throughout the study and give unwieldy results that can upend studies.

Consistency is important. Choose a single sample type for your study. For example, while plasma and serum are both commonly used for immunoassays, their use in samples should not be interchangeable. Plasma has 3-4% more protein than serum. Additionally, plasma and serum are processed differently.

Sample matrices are different for each type. It is best to consider any time and temperature requirements as well. Many biomarkers can degrade at room temperature. In such situations, consider using a cooled centrifuge or keeping your sample on ice or using the freezer.

Adopt a well-strategized storage protocol that does not risk damaging the sample. A sample should be stored at a consistent temperature and not be subject to changes like freeze-thaw cycles.

Filtering the Sample Is Necessary

Filtering the sample can be seen as a part of sample preparation. However, it is important enough for multiplex systems to be mentioned separately. Miniaturization is what makes these multiplex assays tick. It is also what makes filtration necessary.

The microspheres used are 5.6 µm in diameter. The presence of impurities like particulates of that size is possible. These particulates can then interfere with the signal and affect the results. This is one of the reasons creating samples for the Luminex platform is considered “complex”.

Check to see that the Sample Volume is Adequate

A Luminex Bioplex system uses a much lower sample volume than conventional immunoassay methods like ELISA. But there still is a minimum sample volume necessary. Availability and sample volume can be low, especially in the early stages of drug development. It pays to be careful about the available sample volume and ensuring you have enough for the multiplex immunoassay.

Keep Relevant Software Updated

Luminex Bioplex systems use software to manage the process and show the results. This makes the result easy to understand and manage. Since the software is so important, it is necessary to keep it updated to the latest version. Of course, software updates don’t flow out regularly, like some mobile apps. Even so, do periodic checks on the software.

Conduct a Pilot Study

There are times when you can't be sure that the Luminex assay will respond well to the method or protocols. In such cases, it is better to run a pilot study. Also, remember that though these kits are cost-effective for analysis, they are also individually expensive. It is better to be careful with the decision-making and management of the study. 